Wire Gauge (AWG) Calculator

Wire Gauge (AWG) Calculator

Neil Rohan

Available on Google Play
2.7(60)
10,000+ installsFreeProductivity

Updated Jul 14, 2026 · v12.0.12

CompareView on Google Play
Screenshot 1
Screenshot 2
Screenshot 3
Screenshot 4
Screenshot 5
Screenshot 6
Screenshot 7
Screenshot 8
Screenshot 9
Screenshot 10
Screenshot 11
Screenshot 12
Screenshot 13
Screenshot 14
Screenshot 15
Screenshot 16
Screenshot 17
Screenshot 18
Screenshot 19
Screenshot 20
Screenshot 21
Screenshot 22
Screenshot 23

Assists the aviation (A&P) mechanic in determining the correct (AWG) wire size

AWG Calculator IMPORTANT NOTICE: THIS CALCULATOR IS *NOT* A GENERAL PURPOSE WIRE GUAGE CALCULATOR. IT IS INTENDED SOLELY FOR FAA REGISTERED AIRCRAFT WIRING, LIMITED TO THE FOLLOWING FAA APPROVED VOLTAGES: 14VDC, 28VDC, 115VAC AND 200VAC. This app assists the aircraft (A&P) mechanic in determining the correct American Wire Gauge (AWG) wire size for given conditions, according to procedures outlined in FAA Publication AC 43-13 1B (Acceptable Methods, Techniques, and Practices - Aircraft Inspection and Repair), Chapter 11. Conditions include circuit length, current, voltage, wire temperature (known or estimated) and derating factors for both altitude and wire bundle size/loading percentage. The app also contains utilities that enable the aircraft mechanic to determine the following parameters without hands-on use of the AC 43-13 (when field/shop conditions make it impractical). Figures are referenced: - Maximum Wire Length (standard temperature). -- Input parameters: circuit voltage, current, current flow and AWG. -- Output: L1. -- Ref: AC 43-13 1B, Fig 11-2/3 - Maximum Current (standard temperature). -- Input parameters: circuit voltage, current flow, wire length and AWG. -- Output: Max Current. -- Ref: AC 43-13 1B, Fig 11-2/3 - Altitude Deration Factor. -- Input parameter: Max Altitude. -- Output: Altitude Deration Factor. -- Ref: AC 43-13 1B, Fig 11-5 - Bundle Deration Factor. -- Input parameters: Wire Count and Loading Percentage -- Output: Bundle Deration Factor. -- Ref: AC 43-13 1B, Fig 11- - IMAX (elevated temperature). -- Input parameters: ambient temperature, conductor temperature rating and AWG. -- Output: IMAX. -- Ref: AC 43-13 1B, Fig 11-4a/b - Bundle Builder (NEW!) -- Input parameters: number of wires, awg sizes, wire currents, maximum altitude, ambient temperature, wire rating, loading factor -- Output: Bundle IMAX (derated for bundle and altitude) with table for IMAX per wire. -- Ref: AC 43-13 1B, Fig 11-4a/b When a chart does depict data due to input/output parameters exceeding chart limits, data is extrapolated and an appropriate warning ("** extrapolated data") is shown. Disclaimer The user of AWG CALCULATOR for any specific application without an independent verification of its accuracy does so at his/her own risk and assumes any and all liability resulting from such use. No warranty is offered as to the accuracy of results. Users should have a thorough understanding of the relevant theoretical criteria. AWG Calculator Copyright 2023 TurboSoftSolutions https://www.turbosoftsolutions.com

Released
September 6, 2020

5 years on Google Play

Version
12.0.12
Updated
Jul 14, 2026
Content Rating
Everyone
Installs
10,000+
Developer
Neil Rohan
Website
https://www.turbosoftsolutions.com
Email
nrohan49@gmail.com
In-app purchases
No

This app isn't currently appearing in any tracked top charts.

Rating breakdown

5
18
4
6
3
6
2
0
1
30